Combined Nano Particle Sizer and Zeta Potential Analyzer (DLS + ELS)
Overview Package Size120.00cm * 60.00cm * 40.00cm Package Gross Weight50.000kg Lead Time 20 days (1 - 10 Pieces) To be n
- Overview
- Product Description
- Specification
- Packing & Delivery
- Company Profile
- FAQ
Basic Info.
| Model NO. | BXT-N9HD |
| Transport Package | Carton Box/Wooden Box |
| Specification | 1040mm*505mm*335m |
| Trademark | GLOMRO |
| Origin | China |
Packaging & Delivery
Package Size120.00cm * 60.00cm * 40.00cm Package Gross Weight50.000kg Lead Time 20 days (1 - 10 Pieces)To be negotiated ( > 10 Pieces)
Product Description
Product Description
Specification| Model | BXT3100-H | BXT5100-H | BXT5200-H | BXT5500-H | BXT5500-H | BXT5500-L | |
| Enforcestandards | ISO 13320-1:1999 GB/T19077.1-2008 | GB/T 19077-2016/ISO13320:2009 | |||||
| Testscope | 0.1μm-500μm | 0.1μm-600μm | 0.1μm-800μm | 0.01μm-800μm | 0.01μm-1000μm | 0.1μm-1000μm | |
| NumberofDetectorChannels | 62 | 66 | 86 | 86 | 86 | 92 | |
| Ultra-highspeedmotherboard | Ultra-high speed data acquisition motherboard (16bit,200kbs) | ||||||
| Measuringaccuracy | Accuracy,reproducibility,and Dv50 are all superior to ±0.5%(NIST traceable reference samples) | ||||||
| Accuracyerror | ≤1% (National Standard) Sample D50 value) | <1%(NationalStandard Sample D50 value) | |||||
| Repeatabilityerror | <0.5%/National Standard Sample D50 value) | ||||||
| Nobubbleformation | With a bubble-free design,there is no interference from bubbles,resulting in more accurate data. | ||||||
| Mistake-proofing | The instrument has a self-protection function against accidental operation,and it will not respond to accidental operations. | ||||||
| Laserparameters | Impoted fiber-optic output high-power laser λ=635nm,p>20mw | Imported fiber-optic output high-power laser with wavelength of635nm,output power of more than 10mW,and service life of over 50,000 hours. | |||||
| LaserIntelligentManagement System | / | The real-time monitoring system monitors the working status of the instrument. Once it receives a work command, the inteligent management system will instantly activate the laser.The high-performance laser wil reach a stable working state within 3 seconds. | |||||
| Camera | Imported Canon Lenses | ||||||
| Dustproofandshockproofdesign | The whole machine is designed to be dust-proof and shock-resistant. | ||||||
| Operatingmode | One-click fully automatic software operation | ||||||
| opticalpathcalibration | Automatic optical path calibration | ||||||
| Corrosion-resistantdesign (optional) | It canbe equipped with aid resistance,alkali resistance,oil resistance (including alsolvent oils,and resistance to organic solvents (such as acetone, phenol,n-hexane,and all other organic solvents). | ||||||
| Wetmethod | Ultrasound | Frequency: f=40kHz, power p=100W, time: adjustable at wil equipped with ultrasonic anti-dry bum | Frequency:f=40kHz,power:p=80W,time:adjustable at wil equipped with ultrasonic anti-dry burn | ||||
| Cycle,Stiring | Cyclic stirring integrated design, speed: 100-3950 rpm adjustable. | ||||||
| recirculatingflow | Rated fiow:Adjustable from 0-10L/min,rated power:25W | ||||||
| Samplechamber | Designed a self-boiling sample chamber for better dispersion,with acapacity of 190-600mL that can be tested normally. | ||||||
| Light-blocking detection | / | The instrument has a unique feature of real-time light attenuation detection,ensuring that the sample additionismore accurate. | |||||
| Micro-injection | / | The instrument can be equipped with a micro-volume automatic testing device,where 10mililiters can be cycled for testing(optional). | |||||
| Software Function | Analyzingpatterns | This includes free distribution,R-R distribution,and lognormal distribution,as wllas hierarchical statistical modes by category,which meet the different requirements ofdiferent industries for the statistical method of particle size measurement ofthe tested samples. | |||||
| Statisticalmethod | Volume distribution and number distribution are used to meet different industries neds fordiferent statistical methods of prticle size distribution. | ||||||
| Statistical comparison | It can perform statistical comparative analysis on multiple test results,which can clearly show the differences between samples ofdiferent batches, samples before and afer processing.and test resuts a different times.It has strong practicalsignificance for the qualitycontrol of industrial aw materials. | ||||||
| AutomaticDIY Displaytemplates | Users can customize the data to be displayed according to the percentage by size,size by percentage,or percentage by size range to meet the characterization requirements ofdiferent industriesfor particle size testing,such as size distribution consistency,interval cumulative distribution etc. | ||||||
| TestReport | The test report can be exported in various formats such as Word,Excel,Bmp images,and Text documents,alowingfor easy viewingof the test report and referencing of test results in scientific articles. | ||||||
| Multilingual Support | Bilingual language interface support,and other language interfaces can be embedded upon request. | ||||||
| Intelligent operationpattern | t operates fully utomatically without any human intervention,with no human factorsinterfering Youjust need to follow the instructions to ad the sample to be tested,and the repeatability of the test results is better. | ||||||
| Testingspeed | <1 time per minute(excluding sample dispersing time) | ||||||
| Powersupply | 110V-240V(±20V),50Hz-60Hz | ||||||
| Size | 750mm*270mm*315mm | 980mm*410mm*450mm | 800mm*280mm*335mm | ||||
| Weight | 25kg | 30kg | 38kg | ||||
| Model | BXT6100-C | BXT6100-C | BXT6100-C | BXT6100-A | BXT6100-A | BXT6100-H | |
| Enforcestandards | GB/T 19077-2016/S013320:2009 | ||||||
| Testscope | 0.1μm-1250μm | 0.1μm-2000μm | 0.1μm-2800μm | 0.01μm-1250μm | 0.01μm-2000μm | 0.01μm-2800μm | |
| NumberofDetectorChannels | 96 | 96 | 102 | 112 | 127 | 127 | |
| Ultra-highspeedmotherboard | High-speed data acquisition motherboard(16-bit,200 kbps) | ||||||
| Measuringaccuracy | Accuracy,reproducibility,and Dv50 are all superior to ±0.5%(NISTtraceable reference samples) | ||||||
| Accuracyerror | <1%(National Standard Sampie D50 Value) | ||||||
| Repeatabilityerror | <0.5%(National Standard Sample D50 walue) | ||||||
| Nobubbleformation | With a bubble-free design,there is no interference from bubbles,resulting in more accurate data. | ||||||
| Mistake-proofing | The instrument has a self-protection function against accidental operation,and it will not respond to accidental operations. | ||||||
| Laserparameters | Imported fiber output high power Laser with wavelength of 635nm,output power of more than 10mW,and service life of over 50,000 hours. | ||||||
| LaserIntelligentManagement System | The working status ofthe real-time monitoring instrument is monitored,and once the working command is received,the inteligent management system willinstantly turn on the laser.The high-performance laser willreach a stable working state within 3 seconds. | ||||||
| Camera | Imported Canon Lenses | ||||||
| Dustproofandshockproofdesign | The whole machine is designed to be dust-proof and shock-resistant. | ||||||
| Operatingmode | One-click fully automatic software operation | ||||||
| opticalpathcalibration | Automatic optica path calibration | ||||||
| Corrosion-resistantdesign (optional) | It can be quipped with acid,alkali,oil(inclucing al solvent oi)and organic solvent resstance (such as acetone,phenol n-hexane and other organic solvents). | ||||||
| Wetmethod | Ultrasound | Frequency f=40 kHz powerp=80W,time:adjustable at wilk quipped with ultrasonic anti-dry burn | |||||
| cycle.Stiring | Cyclic stirring integrated design, speed: 100-3950 rpm adjustable. | ||||||
| recirculatingflow | Rated flow: Adjustable from 0-10L/min, rated power: 25W | ||||||
| Samplechamber | Designed a self-boiling sample chamber for better dispersion,with a capacity of190-600 mL that can be tested normally. | ||||||
| Light-blocking detection | The instrument has a unique feature of real-time light attenuation detection,ensuring that the sample addition is more accurate. | ||||||
| Micro-injection | The instrument can be equipped with a micro-volume automatic testing device,where 10 mililiters can be cycled for testing (optional). | ||||||
| Software Function | Analyzingpattens | This includes free distribution,R-Rdistribution,and lognormal distribution,as well s hierarchical statistical modes by category,which met the diferent requirements ofdifferent industries for the statistical method of particle size measurement of the tested samples. | |||||
| Statisticalmethod | Volume distribution and number distribution are used to meet different industries’ needs for different statistical methods of particle size distribution. | ||||||
| Statistical comparison | It can perform statistical comparative analysis on multipie test results,which can clearly show the differences between samples ofdiferent batches. samples before and after procsing,and test results a different times.t has strong practical signicance for the qualitycontrol ofindustrial raw materials. | ||||||
| AutomaticDIY Displaytemplates | Users can customizethe data to be displayed according to the percentage by size,size by percentage.or percentage by size range to meet the characterization requirements ofdiferent industriesfor particle size testing,such as size distribution,consistency intervalcumulative distribution,etc. | ||||||
| TestReport | The test report can be exported in various formats such as Word,ExceL.Bmp images and Text documents,alowing for easy viewing of the test report and referencing of test results in scientific articles. | ||||||
| Multilingual Support | Bilingual language interface support,and othe language interfaces can be embedded upon request. | ||||||
| Inteligent operationpattern | It operates fullautomatically without any human intervention,with no human factors interfering.You just need to fllow the instructions to add the sample to be tested,and the repeatability of the test results is better. | ||||||
| Testingspeed | <1 time per minute(excluding sample dispersing time) | ||||||
| Powersupply | 110V-240V(±20V),50Hz-60Hz | ||||||
| Size | 1050mm*325mm*335mm | 800mm*280mm*335mm | 1050mm*325mm*335mm | ||||
| Weight | 45kg | 38kg | 45kg | ||||
| Model | BXT2020-L | BXT2020-H | BXT2020-H | BXT2020-H | |
| Enforcestandards | GB/T 19077-2016/IS013320:2009 | ||||
| Testscope | 0.1μm-800μm | 0.1μm-1250μm | 0.1μm-2000μm | 0.1μm-2800μm | |
| NumberofDetectorChannels | 87 | 101 | 109 | 115 | |
| Accuracyerror | <1%(National Standard Sample D50 value) | ||||
| Repeatabilityerror | <1%(National Standard Sample D50 value) | ||||
| Ultra-highspeeddataacquisition motherboard | With a super-fast data acquisition motherboard,16-bit and a sampling rate of 200kbs,the sample can obtain accurate results within 0.1s in the laser beam. | ||||
| opticalmodel | Full Mie Scattering Theory for the Entire Range,Including High-Concentration Multi-Scattering Dynamic Compensation Technology | ||||
| Filteringmethod | Three-lens technology:Fourier transform lens +filtering lens+standard Fourier transform lens | ||||
| Feedingmethod | Mechanical infinitely variable speed vibration feeding,software controlled. | ||||
| Oil-freeSilentAirCompressor | With dust filtration function,ensuring accurate test results. | ||||
| Colddryer | A freeze dryer can filter out moisture from the air to ensure consistent dispersion, | ||||
| Mistake-proofing | The instrument has a self-protection function against accidental operation,and the instrument does not respond to accidental operations | ||||
| Laseparameters | Imported fiber-optic output high-power laserλ=650nm,p>10nw | ||||
| ConcentrationRange | Minimum light transmission 3%,maximum light transmission 90%(optical density) | ||||
| Dispersionmethod | High-pressure air dispersion | ||||
| Operatingmode | The software operates automatically | ||||
| opticalpathalignment | Automatic optical alignment | ||||
| Software Function | Analyzingpatterns | This includes free distribution,R-R distribution,and lognormal distribution,as wellas hierarchical statistical modes by category,which meet the different requirements of different industries for the statistical method of particle size measurement of the tested samples. | |||
| Statisticalmethod | Volume distribution and number distribution are used to meet different industries'needs for different statistical methods of particle size distribution. | ||||
| Statisticalcomparison | It can perform statistical comparative analysis on multiple test results,which can clearly show the differences between samples of different batches,samples before and after processing,and test results at different times.It has strong practical significance for the quality control of industrial raw materials. | ||||
| AutomaticDIY Displaytemplates | Users can customize the data to be dsplayed according to the percentage by size,size by percentage,or percentage by size range to meet the characterization requirements of different industies for particle size testing,such as size distribution,consistency,interval cumulative distribution,etc. | ||||
| TestReport | The test report can be exported in various formats such as WordExcel,Bmp images,and Text documents,allowing for easy viewing of the test report and referencing of test results in scientific articles. | ||||
| MultilingualSupport | Bilingual language interface support,and other language interfaces can be embedded upon request. | ||||
| IntelligentOperations Mode | It operates fully automatically without any human intervention,with no human factors interfering. You just need to folow the instructions to add the sample to be tested,and the repeatability of the test results is better. | ||||
| Testingspeed | <1 time per minute(excluding sample dispersing time) | ||||
| Size | 700mm*495mm*300rm | ||||
| Weight | 35kg | ||||
| Model | BXT6100-B | BXT6200-B | BXT6100-D | |
| Enforce standards | GB/T 19077-2016/IS013320:2009 | |||
| Test scope | Wet method:0.01μm-2000μm Dry method:0.1μm -2000μm | Wet method:0.01μm-2800μm Dry method:0.1μm -2800μm | Wet method:0.01μm-1250μm Dry method:0.1μm -1250μm | |
| Number of Detector Channels | Wet method:127 Dry method:96 | Wet method:128 Dry method:115 | Wet method:127Dry method:96 | |
| Accuracy and repeatability errors | <±0.5%(National Standard Sample D50 Value) | |||
| Ultra-high speed data acquisition motherboard | With a super-fast data acquisition motherboard, 16-bit resolution, and a sampling rate of 200 kbps, the sample can obtain accurate results within 0.1 seconds in the laser beam. | |||
| No bubble formation | With a bubble-free design, there is no interference from bubbles, resulting in more accurate data. | |||
| Mistake-proofing | The instrument has a self-protection function against accidental operation, and it will not respond to accidental operations. | |||
| Laser parameters | Imported fiber output high-power semiconductor laser with input=635mm, maximum power of 20mw, service life >50,000 hours | Imported fiber output high-power semiconductor laser with input=650mm, maximum power of 20mw, service life >50,000 hours | ||
| Camera | Imported Canon Lenses | |||
| Operating mode | Dry and wet method software one-click full automatic operation | |||
| optical path calibration | Automatic optical path calibration | |||
| Wet method | Ultrasound | Frequency: f = 40 kHz, Power: p = 100 W, Time: adjustable at will; equipped with ultrasonic anti-dry burn | ||
| Cycle/Stirring | Cyclic stirring integrated design, speed: 100-3950 rpm speed adjustable | |||
| Recirculating flow | Rated flow: Adjustable from 0-10L/min, rated power: 25W | |||
| Sample chamber | Designed a self-boiling sample chamber for better dispersion, with a capacity of 190-600 mL that can be tested normally. | |||
| Light-blocking detection | The instrument has a unique feature of real-time light attenuation detection, ensuring that the sample addition is more accurate. | |||
| Micro-injection | The instrument can be equipped with a micro-volume automatic testing device, where 10 milliliters can be cycled for testing (optional). | |||
| Dry method | Dispersion method | High-pressure air dispersion | ||
| Feeding method | Mechanical infinitely variable speed vibration feeding, software controlled | |||
| Oil-free Silent Air Compressor | With dust filtration function to ensure test accuracy, adjustable continuously from 0.1 to 0.8 MPa. | |||
| Filter | A freeze dryer can filter out moisture from the air to ensure consistent dispersion. | |||
| Software Functions | Analyzing patterns | This includes free distribution, R-R distribution, and lognormal distribution, as well as hierarchical statistical modes by category, which meet the different requirements of different industries for the statistical method of particle size measurement of the tested samples. | ||
| Statistical method | Volume distribution and number distribution are used to meet different industries' needs for different statistical methods of particle size distribution. | |||
| Statistical comparison | It can conduct statistical comparative analysis on multiple test results, which can clearly show the differences between samples of different batches, samples before and after processing, and test results at different times. It has strong practical significance for the quality control of industrial raw materials. | |||
| Automatic DIY Display templates | Users can customize the data to be displayed according to the percentage by size, size by percentage, or percentage by size range to meet the characterization requirements of different industries for particle size testing, such as size distribution, consistency, interval cumulative distribution, etc. | |||
| Test Report | The test report can be exported in various formats such as Word, Excel, Bmp images, and Text, allowing for easy viewing of the test report in any setting and for easy referencing of test results in scientific articles. | |||
| Multilingual Support | Bilingual language interface support, and other language interfaces can be embedded upon request. | |||
| Smart Operating Mode | It operates fully automatically without any human intervention, with no human factors interfering. You just need to follow the instructions to add the sample to be tested, and the repeatability of the test results is better. | |||
| Measuring Time | Typical values<10 S | |||
| Ambient temperature | 0°-45°C | |||
| Environmental humidity | 10% to 85% relative humidity (no condensation) | |||
| Power Requirements | 110-240V(±20V,50Hz-60Hz) | |||
| Volume | 1040mm*505mm*335m | |||
| Weight | 50kg | |||
| Testing speed | <1 time per minute(excluding sample dispersing time) | |||
| Model | BXT-N9 | BXT-N9H | |||
| Enforce standards | ISO 13320:2009,GBT 19077-2016 | ISO 13320:2009,GBT 19077-2016 | |||
| Test scope | 0.5-10000nm(It's related to the sample) | 0.5-10000nm(It's related to the sample) | |||
| Concentration Range | 0.1mg/ml-100mg/ml(It's related to the sample) | 0.1mg/L-100mg/L(It's related to the sample) | |||
| Accuracy error | <1%(National Standard Sample Average Particle Size) | <1%(National Standard Sample Average Particle Size) | |||
| Repeatability error | <1%(National Standard Sample Average Particle Size) | <1%(National Standard Sample Average Particle Size) | |||
| Laser | Integrated constant temperature system with maximum power of 50mW, solid laser with wavelengths of 532nm or 405nm (optional) | λ= 405nm, λ=532nm, exclusive dual semiconductor laser dual wavelength, exclusive with temperature control protection | |||
| Detector | A Hamamatsu Photon Counting Detector (High-Sensitivity Photomultiplier Tube) from Japan | A Hamamatsu Photon Counting Detector (High-Sensitivity Photomultiplier Tube) from Japan | |||
| Scattering angle | 90° | 90° | |||
| Data correlator | Physical channel: 512, equivalent channel: 10,000, baseline channel: 8, Sampling and delay time: 1 us to 200 us dynamically adjustable, minimum resolving ability: 6 ns | A high-speed photonic correlator developed by Physical channel: 512, Equivalent channel: 10,000, base line channel: 8, Sampling and delay time: 1 us to 200 us Dynamically adjustable, minimum resolving ability: 6 ns | |||
| Sample chamber | 10mm*10mm*40mm,1-4ml(temperature control protection) | 10mm*10mm,4ml (Temperature control protection) | |||
| Data processing | The optimal fitting cumulative analysis method and the improved normalization algorithm can provide the average particle size and the particle size distribution curve. | The optimal fitting cumulative analysis method and the improved normalization algorithm can provide the average particle size and the particle size distribution curve. | |||
| Software Functions | One-click measurement, automatic optimization of measurement parameters, easy generation of test reports. | One-click measurement, automatic optimization of measurement parameters, easy generation of test reports. | |||
| Output Project | Average particle size, polydispersity coefficient, size distribution curve, and size distribution table, etc. | Average particle size, polydispersity coefficient, size distribution curve, and size distribution table, etc. | |||
| Temperature Range | 0-90℃(The temperature is accurate to±0.1℃) | 8-45℃(temperature is precise 0.1℃) | |||
| Temperature regulation | External Direct Temperature Control, No Need to Open the Case | External Direct Temperature Control, No Need to Open the Case | |||
| Testing speed | <5 time per minute(excluding sample dispersing time) | <1time per minute(excluding sample dispersing time) | |||
| Size | 440mm*245mm*228mm | 390mm*255mm*240mm | |||
| Power | AC100~260V5060Hz.Maximum power 80W | AC100~260V5060Hz. Maximum power 80W | |||
| Use environment | Temperature: 0~45℃, Relative Humidity: 10%-85% (non-condensing) | Temperature: 15°C to 40°C, Relative Humidity: 20% - 70% (without condensation) |


We are based in Shanghai, China, start from 2017,sell to North America(20.00%),Western Europe(15.00%),South America(10.00%),Oceania(10.00%),Northern Europe(10.00%),Eastern Europe(10.00%),South Asia(5.00%),Southern Europe(5.00%),Central America(5.00%),Africa(5.00%),Southeast Asia(5.00%). There are total about 11-50 people in our office.Q2. How can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;Q3.What can you buy from us?
Differential Scanning Calorimeter, Thermogravimetric Analyzer, Differential Thermal Analyzer, Oxygen Bomb Calorimeter, Spot CoolerQ4. Why should you buy from us not from other suppliers?
We have 10 years of experience in design and development. The price preferential benefit There is a lot of goods in stock The service is goodQ5. What services can we provide?
Accepted Delivery Terms: FOB,CFR,CIF,EXW,FAS,CIP,FCA,DDU,Express Delivery,DAF;
Accepted Payment Currency:USD;
Accepted Payment Type: T/T,Credit Card,Western Union;
Language Spoken:English,Chinese